|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Presente / Presents: DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Quebec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com NHG RELAYS 4117-2 29.6 18 20 Features Twin structure of 4117 type. Small size, light weight. Low coil power consumption. PC board mounting. Patent No.: 95319882.0 Ordering Information 4117-2 2C S 1 2 3 12VDC 4 3 Enclosure S: Sealed type Z: Dust cover 4 Coil rated voltage(V) DC:3,5,6,9,12,18,24 1 Part number 4117-2 2 Contact arrangement 2A:2A 2C:2C 2U:2U 2W:2W Contact Data Contact Arrangement Contact Material Contact Rating (resistive) Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation Electrical life Mechanical 2A DPSTNO 2C DPDT(B-M) 2U DPSTNODM 2W DPDTNC-NO AgNi AgSnO2 AgCdO 2A,2C: 10A/120VAC,28VDC ; 2U,2W: 2 10A/120VAC, 28VDC 280W 1200VA 75VDC 380VAC Max. Switching Current:10A 50m Item 3.12 of IEC255-7 105 Item 3.30 of IEC255-7 107 Item 3.31 of IEC255-7 Coil Parameter Coil voltage VDC Coil resistance 10% Pickup voltage VDC(max) (75%of rated voltage ) Release voltage VDC(min) (10% of rated voltage) Coil power consumption W Operate Time ms Release Time ms Dash numbers Rated 003-1000 005-1000 006-1000 009-1000 012-1000 018-1000 024-1000 3 5 6 9 12 18 24 Max. 3.9 6.5 7.8 11.7 15.6 23.4 31.2 9 25 36 85 145 324 576 2 2 2 2 2 2 2 2.25 3.75 4.50 6.75 9.00 13.5 18.0 0.3 0.5 0.6 0.9 1.2 1.8 2.4 2 1.0 10 5 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. 4117-2 Operation condition Insulation Resistance Dielectric Strength Between contacts Between contact and coil Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 100M min (at 500VDC) Item 7 of IEC255-5 Item 6 of IEC255-5 Item 6 of IEC255-5 IEC68-2-27 T Ea est IEC68-2-6 Test Fc IEC68-2-21 Test Ua1 IEC68-2-20 Test Ta method 1 IEC68-2-3Test Ca 50Hz 750V 50Hz 1500V 100m/s2 11ms 10~40Hz double amplitude 1.27mm 10N 235 2 3 0.5s -40~105 85% (at 40 ) 20g Qualification inspection: Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24. Dimensions 3.81 0.150 mm /inch 18max. 0.709max. 29.6max. 1.165max. 14- 1.3 0.051 20max. 0.787max. 0.3 0.012 8.89 0.350 2.4 0.094 0.8X0.8 0.031X0.031 0.8X0.8 0.031X0.031 2.1 0.083 4- 0.7 0.028 8-0.5X0.8 0.02X0.031 5.08 5.08 0.200 0.200 10.16 10.16 4 0.400 0.157 0.400 Dimensions Mounting (Bottom view) Wiring diagram(Bottom view) NOTES 1).Dimensions are in millimeters. 2).Inch equivalents are given for general information only. Reference Data 12 10 Time(msec) 8 6 4 2 Ningbo Huaguan Relay Corporation LTD. |
Price & Availability of 4117-22UZ24VDC |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |